Because Lancer recognises the variety of cleaning
applications, the specification changes ofter required and that
each contract is more akin to a mini-engineering project, this data
should only be considered as guidelines. Further
details can be obtained from Lancer on request.
| Basic Specification |
| Construction |
316L stainless steel throughout
|
| Chamber |
Radius cornered
|
| Water inlets |
Hot, cold and purified water
|
| Heating |
Switchable imersion heaters or, by steam
|
| Dosing control of detergents and additives
|
Automatic via 2 metering pumps (additional
pump optional) |
| Control |
40 user adjustable programs |
| Security |
PIN |
| Water consumption -
normal cycle |
40 Litres
(1400 series)
70 Litres (1600
series)
100 Litres (4500/4800) series
|
| Recirculating pump flow rate |
600-1100 Litres per minute (depending
on model) |
| Electrical connections |
230V or 400V 3-phase
|
|

Chamber Dimensions
h x w x d (mm) |
| 1400 series |
640 x 625 x 625
|
| 1600 series |
855 x 705 x 7055
|
| 4500 series |
1030 x 850 x 850
|
| 4800 series |
850 x 1300 x 850
|
|